Loading...
HomeMy WebLinkAboutTract Map 3883 Lot 32 Updated Field Density Testing . . . Updated REPORT of OBSERVATION and FIELD DENSITY TESTING for RESIDENTIAL GRADING TR 3883; Lot 32 APN: 919-021-007 LD98-078GR June 1, 2000 Prepared for: Chris & Paula Difederico P.O. Box 445 Temecula, CA 92590 (702) 346-6370 (909) 676-9648 Prepared by: Gunvant Thakkar, P.E. 45712 Classic Way Temecula, California 92592 .'. (909) 676-7541 ~~3 l.(rr 2.2- \ ;;; . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 909)676-7541 June 1, 2000 Chris e. Paula Difederico P.O.! Box 445 Temecula, CA 92590 Phone: 702/346-6370 909/676-9648 Project: Compaction Testing & Report Lot 32; Tr 3883 APN: 919-021-007 Dear Mr. Difederico: In accordance with your request, we have prepared this compaction report for the subject property. The report represents a summary of the observations and compaction testing of the fill placed on the proposed grading pad. Field testing and observations indicate the compaction of the soil was performed properly. The soil should perform satisfactorily for the expected usage. The included findings and recommendations have been derived in accordance with generally accepted professional principles and practices in the fields of soil mechanics and foundation engineering. This warranty is in lieu of all other warranties, either expressed or implied. The. opportunity to be of continued services is sincerely appreciated. If you should have any questions or require further information, please contact me at your convenience. Respectfully submitted, Gunvant Thakkar, RCE 52856 '2.. ~ . . INTRODUCTION In accordance with your request, tests have been performed on the fill placed on the rough graded resider'ltial pad. The excavation, fill placement, compaction and testing associated with this phase of the grading was performed during May 17 through May 20, 1999. Remedial grading was performed during May, 2000. This report presents a summary of the testing services provided. PROJECT DESCRIPTION The site will have a single family residence with attached garage constructed on it with associated landscaping and access drive. This structure could consist of a one or two story, wood framed residence founded on a continuous perimeter footings foundation system. GRADING PROCEDURES The observations and test results indicated that the grading was performed in the method consistent with the project specifications. All areas to receive fill were stripped and cleared of vegetation and soft soil prior to placement of soil fill. Keying and benching into natural ground was completed in general compliance with the Uniform Building Code, Appendix Chapter 33. The minimum acceptable degree of compaction content was 90 percent of the maximum density. FlEW DENSITY TESTING Field density testing was performed in accordance with ASTM D1556-64 (Sand Cone Method). The results of the field density tests are presented in Table I of this report. The approximate location of the tests are shown on the Plot Plan, Plate 1. MAXIMUM DENSITY DETERMINATIONS Maximum density 1 optimum moisture determinations were made from representative samples of on-site soils used in the fill operations. The tests were performed in accordance with ASTM D1557- 78 Method. .3 , . . LIMITATIONS lihe findings and recommendations of this report were prepared in accordance with contemporary princ;iples and practices in the field of geotechnical engineering. No other warranty or guarantee is either expressed or implied. Only a portion of the subsurface soils and conditions were evaluated or observed and the conclusions are based upon an interpretation of the soils conditions encountered in the field tests. Conclusions are also based on the assumption that these findings do not vary appreciably in the adjacent areas. However, minor variations may occur: should soil conditions significantly different be encountered in the future, an assessment of the impact on subsequent recommendations should be made. All future grading and fill placement should be performed under the inspection and testing of a registered civil engineer. SUMMARY Our description of grading and backfill operations, as well as testing services, were limited to those grading operations performed May 17 through May 20, 1999. Remedial grading was performed during.May, 2000.The conclusions and recommendations contained herein have been based upon our observation and testing as noted. It is our opinion that the work performed in the areas denoted has generally been accomplished in accordance with U.B.C. Appendix Chapter 33 specifications. No conclusions or warranties are made for areas not tested or observed. Due to periodic site inspections and testing, footing excavations should be inspected by a registered civil engineer prior to concrete placement to verify proper embedment entirely into competent soils. i /,ic0.-- J\ " . . GUNVANT THAKKAR, PROFESSIONAL ENGINEER 45712 Classic Way, Temecula, California 92592 (909) 676-7541 Mr. Difederico Maximum Density Optimum Moisture Content (pct) (%) 128.5 10.5 Eleva- tion (Feet) MaxDry Density (pcf) Water Content (%) Dry Density (pcf) Relative Method Compac- Tion (%) 1. Key 128.5 10.2 116.9 91 SC 2. Key 128.5 10.5 115.7 90 SC 3. Key 128.5 10.1 118.2 92 SC 4. 4 128.5 9.9 119.5 93 SC 5. 5 128.5 9.8 116.9 91 SC 6. FS 128.5 10.1 118.2 92 SC 7. FS 128.5 10.2 116.9 91 SC 8. FS 128.5 10.3 115.7 90 SC 9. FS 128.5 10.1 118.2 92 SC 10. FS 128.5 9.9 119.5 93 SC 11. FS 128.5 10.1 118.2 92 SC 12. Key 128.5 10.5 118.2 92 SC 13. Key 128.5 10.2 116.9 91 SC 14. 4 128.5 10.5 119.5 93 SC 15. 5 128.5 10.7 116.9 91 SC 16. FS 128.5 11.2 118.2 92 SC 17. FS 128.5 10.9 116.9 91 SC s . . :;;. . . ; [-/5 --- <:l Qp. WINC'HE'S TE,e RD, ~ i!1 ~~ / ~p.Q-\) . 't ~ ~ ( \(l'I~ \:.; ~ ~I,.., :j ~RLl ti "I: / ~ Sl \l v F\\J..E: OL IIER~ J'!J,' , (T~ I \!) , C:( 6~N. KEI1RNE'I I <:t' I ~ \ DATE: 5-11-'31 I SITE LOCATION PLAN I PLATE: 2 ~ . . . .' ,-:::. '. ~ . ..' 'u ~ ~ ~ .... ..J~; -,. '. " l _""-----. \_ t. \-'-'.""-~~-:::=-':::.-."". e:ft9 ., ,> .... LEGEND . APPROXIMATE TEST LOCATION Chvi~ PLAN DATE: 6-'1'- 00 TEST LOCATION D,.{7ede\' i Co PLATE: I "1